Enfield Doors FD120
Technical Specification
- Make: Enfield Doors
- Model code: FD120
- Fire rating: 120 mins
120 minutes fire resistance (Integrity) 60mm Certified core to BS 476 Pt22:1987 or BS EN 1634-1:2014 Intumescent strips in the frame or the door (not both) Certified glazing (insulating / non insulating) Available as a pre hung assembly Must be installed by a competent person In 2 storey homes doors leading from an integral garage into the house must be fire resistant. New build or renovated properties with 3 story’s or more, including loft conversions, must have a fire doors to every habitable room off the stairwell
Read moreMake | Enfield Doors |
---|---|
Manufacturer | Enfield Doors |
Category | Fire Protection>Fire Doors |
Model code | FD120 |
Fire rating | 120 mins |
Additional info |
|