Task force tips A03ST-F LOW-LEVEL STRAINER 5.0"STORZ
Technical Specification
- Make: Task Force Tips
- Model code: A03ST-F
- Size (in.): 5
- Thread Type: Storz
Flotation device allows TFT high volume low-level strainer to collect clean water from ponds, lakes and rivers. The strainer inlet, made of hard anodized and powder-coated aluminum, hangs 18" below water level to avoid sucking surface air and bottom debris. Capable of supporting up to 30 ft of hose, the strainer extends well beyond safety ledges of residential ponds. The clog-resistant stainless steel filter has over twice as much flow area as a 6" hose. This keeps friction loss down to 0.5 psi (1" Hg) at 1500 gpm and reduces the potential for air vortexes to form. Oversized sealed ball pivot allows 45° range of hose angle without constricting the flow path. Rugged polyethylene float is yellow for high visibility and nests compactly over the strainer for minimal storage space. Float removal is not necessary for low level use, although a tethered latching hinge pin allows the float to be removed or installed instantly if desired.
Read moreMake | Task Force Tips |
---|---|
Manufacturer | Task Force Tips Inc. |
Category | Fire and Rescue>Strainers |
Model code | A03ST-F |
Size (in.) | 5 |
Thread Type | Storz |
Additional info |
Flotation device allows TFT high volume low-level strainer to collect clean water from ponds, lakes and rivers. The strainer inlet, made of hard anodized and powder-coated aluminum, hangs 18" below water level to avoid sucking surface air and bottom debris. Capable of supporting up to 30 ft of hose, the strainer extends well beyond safety ledges of residential ponds. The clog-resistant stainless steel filter has over twice as much flow area as a 6" hose. This keeps friction loss down to 0.5 psi (1" Hg) at 1500 gpm and reduces the potential for air vortexes to form. Oversized sealed ball pivot allows 45° range of hose angle without constricting the flow path. Rugged polyethylene float is yellow for high visibility and nests compactly over the strainer for minimal storage space. Float removal is not necessary for low level use, although a tethered latching hinge pin allows the float to be removed or installed instantly if desired. |
Download PDF version Download PDF version |
- See other Task Force Tips products
- Task Force Tips Valves
- Task Force Tips Monitors
- Task Force Tips Nozzles
- Task Force Tips Adapters/Fittings
- Task Force Tips Apparatus and Equipment Accessories
The New Future For Fire Agencies
DownloadThe Eight Key Trends in Fire Detection in 2023
DownloadA Digital Platform to Improve Fire Safety Compliance and Inspections
DownloadOvercoming the Challenges of Fire Safety in the Paper Industry
DownloadCarbon Monoxide: Creeping Killer Caught In The Act
Download