Pozhtechnika 113-26 FOAM FIRE EXTINGUISHER MIG 50lt
Technical Specification
- Make: Pozhtechnika
- Model code: 113-26
- Extinguishing Agent: Foam
- Type: Stored Pressure
FOAM FIRE EXTINGUISHER MIG 50lt Stored pressureFire extinguishing capability on suppression of model seats of fire of a class A and B: 4A, 233B.Mechanical foam fire extinguishers MIG are charged with a film-forming synthetic fluorinated foaming agent - Sthamex AFFF. low separation factor accounts for rapid formation of a water film which has the ability to spontaneously spread and coat the oil product, prevent evaporation and formation of a vapour-air mixture, decrease the extinction time and cool the fire zone. If the foam layer is breached, surface tension forces will cause the foam to cover the whole of liquid oil product. Foamer solution absorbs very little of the flammable substances, so it can be used for subsurface suppression. this solution has extremely low surface tension and better firefighting properties than alternatives in the market. these solutions are almost ph neutral (рН=6.5-8.0), which makes them safe for humans and for the environment. Sthamex AFFF foamer is designed to fight class a and b fires by isolating the burning surface and thus preventing hot vapour-air mixture generation. It is stable and resistant to thermal radiation emitted by combustible materials with a high content of polar additives, such as alcohol, etc. main applications of the fire extinguishers are chemical and petrochemical industries, airfields, as well as any application where a need may arise to extinguish large oil or oil product spills, or to timely prevent ignition of flammable liquids. It is recommended for use on ships, in ports and in the offshore zone.The fire extinguishing capability of the fire extinguisher is confirmed with the certificate of conformity.Range of temperatures of operation: from plus 5 to plus 50 ° C.The cylinder of the fire extinguisher is certified on compliance to requirements of the Technical Regulation TR TS 032/2013 "TR on safety of high pressure equipment ". According to the existing standard rate, powder fire extinguisher MIG E marking of a cylinder is executed mechanically and contains the following records: logo of JSC Pozhtekhnika, mark of conformity of "EAC", name of a cylinder, serial number of a cylinder, month and year of production of a cylinder, year of the following re-examination of a cylinder, range of temperatures of operation of the cylinder "from-50 C to +50 C", working and trial pressure of a cylinder, weight and amount of an empty cylinder.
Read moreMake | Pozhtechnika |
---|---|
Manufacturer | Pozhtechnika |
Category | Fire Protection>Extinguishers |
Model code | 113-26 |
Extinguishing Agent | Foam |
Type | Stored Pressure |
Additional info |
FOAM FIRE EXTINGUISHER MIG 50lt
Stored pressure
Fire extinguishing capability on suppression of model seats of fire of a class A and B: 4A, 233B. Mechanical foam fire extinguishers MIG are charged with a film-forming synthetic fluorinated foaming agent - Sthamex AFFF. low separation factor accounts for rapid formation of a water film which has the ability to spontaneously spread and coat the oil product, prevent evaporation and formation of a vapour-air mixture, decrease the extinction time and cool the fire zone. If the foam layer is breached, surface tension forces will cause the foam to cover the whole of liquid oil product. Foamer solution absorbs very little of the flammable substances, so it can be used for subsurface suppression. this solution has extremely low surface tension and better firefighting properties than alternatives in the market. these solutions are almost ph neutral (рН=6.5-8.0), which makes them safe for humans and for the environment. Sthamex AFFF foamer is designed to fight class a and b fires by isolating the burning surface and thus preventing hot vapour-air mixture generation. It is stable and resistant to thermal radiation emitted by combustible materials with a high content of polar additives, such as alcohol, etc. main applications of the fire extinguishers are chemical and petrochemical industries, airfields, as well as any application where a need may arise to extinguish large oil or oil product spills, or to timely prevent ignition of flammable liquids. It is recommended for use on ships, in ports and in the offshore zone. The fire extinguishing capability of the fire extinguisher is confirmed with the certificate of conformity. Range of temperatures of operation: from plus 5 to plus 50 ° C. The cylinder of the fire extinguisher is certified on compliance to requirements of the Technical Regulation TR TS 032/2013 "TR on safety of high pressure equipment ". According to the existing standard rate, powder fire extinguisher MIG E marking of a cylinder is executed mechanically and contains the following records: logo of JSC Pozhtekhnika, mark of conformity of "EAC", name of a cylinder, serial number of a cylinder, month and year of production of a cylinder, year of the following re-examination of a cylinder, range of temperatures of operation of the cylinder "from-50 C to +50 C", working and trial pressure of a cylinder, weight and amount of an empty cylinder. |
Download PDF version Download PDF version |
- See other Pozhtechnika products
- Pozhtechnika Fire Cabinets
- Pozhtechnika Vehicles
- Pozhtechnika Foam Equipment
- Pozhtechnika Ladders
- Pozhtechnika Hoses
The New Future For Fire Agencies
DownloadThe Eight Key Trends in Fire Detection in 2023
DownloadA Digital Platform to Improve Fire Safety Compliance and Inspections
DownloadOvercoming the Challenges of Fire Safety in the Paper Industry
DownloadCarbon Monoxide: Creeping Killer Caught In The Act
Download