Pavlis a Hartmann s.r.o. Recess mounted D19 and D25 hydrant systems Recess mounted D19 and D25 hydrant systems

Technical Specification

Features:
  • Make: Pavlis a Hartmann s.r.o.
  • Model code: Recess mounted D19 and D25 hydrant systems
  • Type: Wall
Additional info:

Frame of square profiles fitted with a swinging arm with a reel and a door. Two anchors are used to fix the frame to the wall or plaster board using dowels and installation foam. Pressurized water supply brought through the centre of the reel enabling immediate use of the system. 19 or 25 mm PH – stabil D semi-rigid hose. Nickel-plated brass ball valve (D19-3/4” systems; D25-1” systems). Combined D25 fire nozzle consisting of a polypropylene body and revolving head. The revolving head makes it possible to set a jet or spray stream with an adjustable spraying angle within the range 0 – 110° and to shut off the nozzle. Connection hose used to connect the system to water main.   Recess mounted hydrant system D19 650 x 650 x 175 mm – hose of 20 or 30m length can be used. Recess mounted hydrant system D25 650 x 650 x 275 mm – hose of 20 or 30m length can be used.Inspection of hydrant systems is to be undertaken by a trained person in accordance with applicable standards and regulations.

Read more
Make Pavlis a Hartmann s.r.o.
Manufacturer Pavliš a Hartmann s.r.o.
Category Fire Protection>Hydrants
Model code Recess mounted D19 and D25 hydrant systems
Type Wall
Additional info
  • Frame of square profiles fitted with a swinging arm with a reel and a door. Two anchors are used to fix the frame to the wall or plaster board using dowels and installation foam. Pressurized water supply brought through the centre of the reel enabling immediate use of the system.
  • 19 or 25 mm PH – stabil D semi-rigid hose.
  • Nickel-plated brass ball valve (D19-3/4” systems; D25-1” systems).
  • Combined D25 fire nozzle consisting of a polypropylene body and revolving head. The revolving head makes it possible to set a jet or spray stream with an adjustable spraying angle within the range 0 – 110° and to shut off the nozzle.
  • Connection hose used to connect the system to water main.

 

  • Recess mounted hydrant system D19
    • 650 x 650 x 175 mm – hose of 20 or 30m length can be used.
  • Recess mounted hydrant system D25
    • 650 x 650 x 275 mm – hose of 20 or 30m length can be used.
      Inspection of hydrant systems is to be undertaken by a trained person in accordance with applicable standards and regulations.