No fire suppression system is complete without the correct suppression agent tanks; they are used to store the suppression agent and play a vital role in the dispersion of the agent upon system activation. In this post, Ardent Vehicle Fire Protection will look at the common issues affecting agent tanks and the importance of frequent maintenance and inspection. Stored pressure and cartridge operated tanks are commonly use in vehicle fire suppression systems.

Both types of agent tank will perform well when used in the right application and environment. However, it is important to understand their key differences.

Understanding Agent Tank Types

  • Stored pressure tanks

In stored pressure tanks, the suppression agent is stored in the same canister as the propellant, typically compressed nitrogen gas. This gas carries the agent from the cylinder, through the nozzles, to the targeted fire hazard area. A pressure gauge is fitted to the tank to allow operators and maintenance personnel to check that the tank is properly pressurized, this can be done by simply verifying that the needle on the gauge is in the green segment.

  • Cartridge operated tanks

Cartridge operated units store the extinguishing agent in a non-pressurized container and the propellant gas in a separate cartridge. When the system is activated, the propellant cartridge pressurizes the agent tank. The pressure within the agent tank rises until the outlet rupture disc pressure is reached, thereby allowing the pressurized agent to be propelled through the distribution network. Cartridge operated tanks cannot be visually inspected to ensure they are properly pressurized.

dry chemical agent

Ardent Dry Chemical powder uses high quality manufacturing techniques to produce finely milled powder

Settling and compaction (time consolidation) can occur over time in both stored pressure and cartridge operated tanks using dry chemical extinguishing agent. This is due to vibration on vehicles and mobile plant. While suppression agent tanks are designed to counteract this, excessive compaction can affect the performance of the fire suppression system and can cause it to fail. The Ardent Dry Chemical powder uses high quality manufacturing techniques to produce a more finely milled powder.

This milling process means that compaction is less severe, and the system is able to discharge easily and efficiently. Milling also contributes to the higher dispersion rates of the dry chemical agent, aiding coverage of the fire hazard areas. Shock and vibration are commonly observed on vehicles, especially off-road vehicles and plant. This is major concern to anything that is bolted to the vehicle, such as extinguishing agent tanks, and can lead to part failure, metal fatigue, and system failure

Shock and Vibration

Thorough testing is needed to ensure they perform under these challenging conditions. At Ardent, the in-house Research and Development team carefully analyze environmental conditions that may impact the fire suppression systems during the design process, ensuring that all of the systems are capable of withstanding the challenges. Loss of pressure can occur within fire suppression systems for a number of reasons, including manufacturing defects, damage to the system or shock and vibration.

If propellant gas leaks are not detected, this could result in the pressure in the extinguishing agent tank dropping below the threshold for fire suppression system activation. Just like the vehicles that they are designed to protect, all fire suppression systems require periodic inspection and maintenance.

Inspection and testing

NFPA Standard No. 17 outlines the inspection requirements for stored pressure and cartridge operated systems

National Fire Protection Association (NFPA) Standard No. 17, the Standard for Dry Chemical Extinguishing Systems, outlines the monthly and semi-annual inspection requirements for both stored pressure and cartridge operated systems. In addition, every 10 years all pressurized cylinders used in fire protection applications are legally required under the British/European Standard BS EN 1968:2002 to be hydrostatically tested.

This tests the strength and integrity of the pressurized cylinder to ensure that they are in safe working condition. The responsibility for hydrostatic testing lies with the person in possession of the cylinder, and failure to test the cylinders can lead to fines of up to £5,000 and, in some cases, imprisonment.

disastrous consequences

This testing is vital for pressurized containers, as, over time, corrosion and cracking can cause cylinders to fail, leading to disastrous consequences such as explosions. In cases where a tank becomes damaged, it is also important to test the cylinder in order to ensure that is still in good, safe, working order.

Download PDF version Download PDF version

In case you missed it

Siemens Expands Fire Safety With Danfoss Acquisition
Siemens Expands Fire Safety With Danfoss Acquisition

Siemens Smart Infrastructure has completed the acquisition of Danfoss Fire Safety, a Denmark-based specialist in fire suppression technology. This strategic step will boost growth...

Specification And Installation: The Key To Effective Door Controls
Specification And Installation: The Key To Effective Door Controls

Safe and seamless movement in our built environment hinges on accurately specified and installed door hardware, explains Russell Marks, managing director of Boss Door Controls. Wi...

AEI Cables: Fire Safety And Building Compliance
AEI Cables: Fire Safety And Building Compliance

Many of the new requirements under the new Building Safety Act 2022 are still not understood by those making critical decisions in the fire safety supply chain, says cable supplier...

vfd