Smoke alarms are a crucial component of safety in a home, as these fire-protection devices will automatically detect and alert users of the presence of smoke and can save a life in the event of a fire.

When placed in the right location, the smoke alarm could additionally aid firefighters in quickly finding the fire in the home, allowing them to better focus their efforts.

audio sound

An audio sound is emitted when residential or commercial Smoke Alarms are activated, if no one is at the property to investigate the activated alarm, the potential fire continues. 

Make the home safer and stop up to 40% of home fires by installing a Smoke Alarm Smart Switch.

Smoke Alarm Smart Switch

The Smoke Alarm Smart Switch monitors the Smoke Alarm, Heat Detector, or Carbon Monoxide activity

The Smoke Alarm Smart Switch monitors the Smoke Alarm (Photo Electric or Iodisation), Heat Detector, or Carbon Monoxide activity, via a standard interconnect cable or wireless communication. 

After 60 seconds of alarming, the Smoke Alarm, Carbon Dioxide, or Heat Detector Alarm will trip the Smoke Alarm Smart Switch and turn off what accounts for 40% of house fires - electricity! (NSW Fire and Rescue).

The Smoke Alarm Smart Switch transforms the standard Smoke Alarms into a 24/7 monitoring system with minimal expense to the end-user as it utilizes existing Smoke Alarms.

switch design and features

The Smoke Detector Safety Switch is specifically designed to protect both people and property from damage or injury in case of a particle fire by monitoring the hard-wired smoke alarm activity via the interconnect terminal on the smoke detector.

  • SSP-1 must be linked up to the chosen c/b via physically linking the drive arm.
  • Active (A) and neutral (N) must be wired with the correct polarity.
  • In 2-3 phase installations, the same phase must be used on the SSP-1 as the hard-wired smoke alarms.
  • A minimum cable size of 1mm must be used.
  • A maximum of 10 hard-wired smoke detectors may be connected to the SSP-1.

Observation and compliance

When installing and operating the Smoke Detector Safety Switch, the following must be observed and complied with:

  • The unit must be properly installed by a qualified electrician and accordance with the detailed instructions in this manual.
  • The unit must be tested and reset at least once a month.
  • The unit must never exceed 4 test and rest operations per minute.
  • The protection device must not be tampered with or repaired by anyone other than the manufacturer.
  • The unit must not have LINE conductors connected to the DC input terminals.
  • This product should not be seen as a replacement for safe electrical practices.
Download PDF version Download PDF version

In case you missed it

Siemens Expands Into Fire Safety With Danfoss Buy
Siemens Expands Into Fire Safety With Danfoss Buy

Siemens Smart Infrastructure has agreed to acquire Danfoss Fire Safety, which specializes in fire suppression technology and is a subsidiary of Denmark-based Danfoss Group. The ac...

The Dingell Act's Impact: Practical Benefits For Fire Professionals
The Dingell Act's Impact: Practical Benefits For Fire Professionals

The Dingell Act, signed into law in 2019, has far-reaching implications, including effects on fire management and emergency services. Officially named the John D. Dingell, Jr. Cons...

Prevent Downtime With Teledyne FLIR Thermal Imaging
Prevent Downtime With Teledyne FLIR Thermal Imaging

When production halts unexpectedly, it disrupts the entire supply chain, causing delays in product delivery and potential loss of customer trust. Financially, the costs can be sub...

vfd