With a pump outlet, the divider is used to supply several pressurized water lines. The most commonly used dividers have 2 or 3 outlets and are equipped with quick couplings at the inlet and outlets. Dividers are usually equipped with shut-off valves on each outlet to open or close the water supply or to switch equipment. With a pump outlet, the divider is used to supply several pressurized water lines.

These dividers exist with several valve models, either ball valves, clappered valves or full water way valves. The most bulky are the full water way valves followed by the clappered valves. Dividers with full water way valves are the most expensive to build, but apart from their size they have the advantage of straight-through flow, which means less pressure drop (pressure drop).

die-cast aluminum alloy

The same applies to ball valves, which have a full passage through the fluid stream. Apart from the question of cost, what differentiates them is the slow closing of the clappered valve, thus avoiding water hammer (overpressure in the upstream pipelines), as in the case of ball valves, as for clappred valves, water hammer can be avoided by ensuring gradual closing, which is what the German and American fire brigades do.

These dividers are equipped with feet that maintain a horizontal position on the floor

As for the French firemen, POK has never observed them bending to close a ball valve, it is by kicking on the handle that they operate. The plastic spheres of the Americans are not resistant to this, nor are even the operating handles, which is why the company builds its handles out of die-cast aluminum alloy that does not break on impact. These dividers are equipped with feet that maintain a horizontal position on the floor. 

valve divider manufacturing

These feet were in the shape of an inverted truncated cone in which the company discovered a disadvantage; when falling on the ground the part of the foot intact with the body of the divider can create a crack on the body leading to the explosion and the uncoupling of the foot with the body when the divider is put in water. To avoid this inconvenience POK has modified the shape of the foot to transfer the break in the middle of the foot.

All of POK’s valve dividers with a mass of more than 3.5 kilograms are equipped with this device, giving our valve divider manufacturing an excellent safety of use. Both the inlet and the outlets of the company’s valve manifolds are threaded, which makes it possible to attach all types of fittings with all diameters from DN20 to DN200 and two valve outlets up to five outlets. In large valve diameters, beyond DN100, the valves are equipped with reducers for smoother operation.

meet all needs

All these dividers are made of aluminum alloy which makes them very light. There are, however, some exceptions such as the US NAVY divider built in bronze, a bronze specified by the US Navy. Customers will find at POK a complete range to meet all of the customer’s needs and ideas.

Download PDF version Download PDF version

In case you missed it

Siemens Expands Fire Safety With Danfoss Acquisition
Siemens Expands Fire Safety With Danfoss Acquisition

Siemens Smart Infrastructure has completed the acquisition of Danfoss Fire Safety, a Denmark-based specialist in fire suppression technology. This strategic step will boost growth...

Specification And Installation: The Key To Effective Door Controls
Specification And Installation: The Key To Effective Door Controls

Safe and seamless movement in our built environment hinges on accurately specified and installed door hardware, explains Russell Marks, managing director of Boss Door Controls. Wi...

AEI Cables: Fire Safety And Building Compliance
AEI Cables: Fire Safety And Building Compliance

Many of the new requirements under the new Building Safety Act 2022 are still not understood by those making critical decisions in the fire safety supply chain, says cable supplier...

vfd