Download PDF version

In this short article, Quelfire looks at what passive fire protection is and what it covers, the use of the term ‘fire stopping’, and the introduction of the term ‘service penetration seal’.  

passive fire protection

The term passive fire protection refers to a set of systems and measures that are designed to limit the spread of fire, smoke, and the amount of damage caused by fire in a building.

Passive fire protection systems are built into the structure of a building and are intended to contain fires and prevent them from spreading to other parts of the building known as compartmentation. Although passive fire protection can be used to describe what we provide, it is an umbrella term that covers many different aspects of fire safety.

Passive fire protection measures

Passive fire protection measures include, but are not limited to:

  • Intumescent fireproofing: This protects the structure of the building by using protective coatings on structural steel.
  • Linear gaps and cavity barriers: Sealing any imperfections of fit, prevents fire or smoke from spreading via walls.
  • Compartmentation: To contain the fire and smoke in one area, the building must be divided into areas of manageable risk using fire-rated walls and floors.
  • Fire doors: Fire doors provide a clear means of escape by preventing the passage of fire and smoke into stairwells.
  • Firestopping: This involves sealing around any pipes, ducts, or cables that pass through a compartment wall or floor.

Under the passive fire protection umbrella, fire stopping (or fire stopping) is the term commonly used in the industry to describe our solutions. It has been around for decades and thus, some people may argue that it is quite outdated.

The history of fire-stopping

It also imposed a maximum number of stories per house for a fixed number of abodes to eliminate overcrowding"

Passive fire protection measures, although not as prominent or advanced as the current times, have been around for centuries. For example, when the Great Fire of London destroyed the city in September 1666, the Act for the Rebuilding of the City of London was passed a year later in February 1667.

This was one of the earliest recordings of using fewer combustible materials to build, “It proposed that all new buildings had to be constructed of brick or stone against the future perils of fire. It also imposed a maximum number of stories per house for a fixed number of abodes to eliminate overcrowding.

Polyurethane foam with a retardant material

However, the push for change to firestopping in buildings began in March 1975: the date of the Browns Ferry Nuclear Power Plant Disaster.

At the time, polyurethane foam with a retardant material applied to the face was used to firestop the power plant’s service penetrations. Similar products still exist today, widely known as fire foam or ‘pink foam’.

Service penetration sealing

Firestopping has become a prominent term used in the industry and although it can be used to describe what Quelfire provides, it feels that it is too generic a term and may be misleading for someone who is not familiar with fire safety.

Quelfire believes service penetration sealing to be the most accurate term because it is the most descriptive. It means retaining the fire rating of walls and floors by sealing service penetrations with the appropriate fire-stopping system tested for those particular applications.

Download PDF version Download PDF version

In case you missed it

Siemens Expands Into Fire Safety With Danfoss Buy
Siemens Expands Into Fire Safety With Danfoss Buy

Siemens Smart Infrastructure has agreed to acquire Danfoss Fire Safety, which specializes in fire suppression technology and is a subsidiary of Denmark-based Danfoss Group. The ac...

The Dingell Act's Impact: Practical Benefits For Fire Professionals
The Dingell Act's Impact: Practical Benefits For Fire Professionals

The Dingell Act, signed into law in 2019, has far-reaching implications, including effects on fire management and emergency services. Officially named the John D. Dingell, Jr. Cons...

Prevent Downtime With Teledyne FLIR Thermal Imaging
Prevent Downtime With Teledyne FLIR Thermal Imaging

When production halts unexpectedly, it disrupts the entire supply chain, causing delays in product delivery and potential loss of customer trust. Financially, the costs can be sub...

vfd