Download PDF version

Kentec Electronics, the manufacturer of innovative life safety solutions, has introduced a range of new features to its cutting-edge Taktis analog addressable fire alarm control panel.

Packed with innovative new functionality to protect even the most complex buildings, Taktis is now the perfect solution for a wide range of applications including schools, hospitals, multi-site retail, and critical national infrastructure, as well as commercial and industrial facilities.

Fire alarm control panel

The critical signal paths of a control panel are the lifeline of an entire fire detection system and issues with power supplies, communication modules and control circuits can have catastrophic consequences.

The critical signal paths of a control panel are the lifeline of an entire fire detection system 

To counter any disruption, the highest levels of redundancy have been incorporated into Taktis, which has multiple back-up microprocessors to eliminate the possibility of a single point of failure with the main microprocessor. Even if its touchscreen display fails, Taktis will continue to operate in reduced functionality mode, the loops will continue to operate and, if a detection device is activated, the panel and other panels on the network will be notified of the alarm condition. 

Enhancing fault tolerance

Taktis enables large installations to be fully standards compliant. EN 54-2 states that a system fault should not result in the loss of more than 512 detectors and while this is fine for installations with a single control panel with less than 512 connected devices, large installations can have many thousands of fire detection devices with multiple fire alarm control panels.

Thanks to Kentec’s research and development, Taktis can now network up to 127 control panels and incorporates a fully redundant signal path using INS to mitigate risk, enhance fault tolerance and ensure that alarms are received across the network and importantly to the Alarm Receiving Centre.

Activating release mechanism

The latest version of Taktis also complies with the highest provisions of BS 7273-4

The latest version of Taktis also complies with the highest provisions of BS 7273-4, which applies to electrical control arrangements for actuation of mechanisms that unlock, release or open doors in the event of fire. Adhering to BS 7273-4 is increasingly important, as Annex A is now normative. 

There are three categories of actuation outlined in BS 7273-4, with Category A requiring failsafe operation under the most severe fault conditions. Through advanced cause and effects, the latest version of Taktis meets all the requirements of Category A. This means that door release mechanisms will continue to operate in the event of a fire, or during any event that leads to a fault on the critical signal path that could prevent a fire signal activating a release mechanism.

Full-scale evacuation

The fire and rescue service in England attended 229,844 incidents in the year ending March 2022 that turned out to be false alarms. They can be particularly disruptive in hotels and similar accommodation-based businesses such as student accommodation and sheltered housing, so Taktis now boasts a ‘hotel mode’ feature. 

In the case of a false alarm, this stops other alarms initiating a full-scale evacuation

When Taktis is in this setting and a detection device activates, only the sounder in the room concerned will initially operate, while Taktis notifies where the event has taken place. A predetermined time period gives a competent person an opportunity to investigate and, if the activity causing the detector activation stops within that timeframe, the sounder will return to standby and Taktis will clear. In the case of a false alarm, this stops other alarms initiating a full-scale evacuation.

Reducing false alarms

Alongside levels of panel & network redundancy, BS 7273-4 Category A compliance and its ability to reduce false alarms, Kentec hasn’t forgotten the importance of ease of use. As such, the Taktis full-color seven-inch color touchscreen has several additional customizable features particularly useful for smoke control operation and can be programmed in a wide variety of languages. This intuitive interface renders the system easy to use even for those with minimal or no training. 

"The latest version of Taktis rubberstamps our commitment to providing the most advanced fire alarm control panel technology possible," commented Derrick Hall, director of sales and marketing at Kentec Electronics. "Taktis has become increasingly popular with members of the Kentec Installation Partner (KIP) Programme because its features make their lives easier and deliver significant benefits for end users. I would therefore encourage other fire detection and alarm installation professionals to take another look at Taktis."

Download PDF version Download PDF version

In case you missed it

Siemens Expands Fire Safety With Danfoss Acquisition
Siemens Expands Fire Safety With Danfoss Acquisition

Siemens Smart Infrastructure has completed the acquisition of Danfoss Fire Safety, a Denmark-based specialist in fire suppression technology. This strategic step will boost growth...

Specification And Installation: The Key To Effective Door Controls
Specification And Installation: The Key To Effective Door Controls

Safe and seamless movement in our built environment hinges on accurately specified and installed door hardware, explains Russell Marks, managing director of Boss Door Controls. Wi...

AEI Cables: Fire Safety And Building Compliance
AEI Cables: Fire Safety And Building Compliance

Many of the new requirements under the new Building Safety Act 2022 are still not understood by those making critical decisions in the fire safety supply chain, says cable supplier...