Everyone knows cleaning turnout gear twice a year is recommended by the NFPA, but do users think about hoods too?

It's easy to forget this small piece of gear, but that doesn't make it any less important! Follow these 4 quick and easy steps to get the fire hood properly cleaned.

Step by Step 

Tools Needed:

  • Examination gloves, apron, & safety glasses.
  • A large utility tub or programmable extractor that doesn't have a G-Force that exceeds 100 G.

Step 1: Preparation

  • Observe necessary universal precautions.
  • Hoods may be hand or machine-washed.
  • Hoods may be washed independently or combined with a load of liners.

Step 2: Wash Hood

Hand Washing

  • Fill a large utility tub with warm water, being cautious never to exceed 40°C or 105°F.
  • Add specialized detergent (approved for use on PPE with a pH between 6.0 and 10.5) to the tub at the label's recommended ratio.
  • Pre-sthe oak hood for a minimum of 10 minutes.
  • Wearing protective gloves, gently rub materials until all areas have been cleaned.
  • Rinse thoroughly until all suds are removed.
  • Lightly squeeze out excess water.

Extractor Washing

  • Hoods may be washed independently or with liners.
  • Load the basket so that when looking through the glass door, it is ¾ full.
  • Power on the extractor.
  • Select the appropriate pre-programmed selection (refer to the manufacturer's user guide for recommended settings).
  • If an automated pump is not present, manually add approved detergent as the machine is filling with water (refer to the detergent's directions for appropriate detergent-to-water ratio).

Step 3: Remove & Inspect

  • Always inspect the hood after each wash to ensure it is thoroughly cleaned - the user may rewash it as necessary. 
  • Ensure all soap was removed - if soap suds remain, rinse as necessary until the hood is sud-free. 
  • Hoods should be taken out of service if contaminants cannot be removed or any physical damage is found.

Step 4: Drying

  • Air-drying is best in an air-drying cabinet or a dark space with good ventilation. Users may also lay on a drying rack or somewhere else that promotes the draining of water from the hood.
  • Do not dry hoods in direct or indirect sunlight, fluorescent light, or UV light.
  • Machine drying should be done using a "no heat" or "air dry" option when available.
  • Temperature should never exceed 40°C or 105°F.

Dos & Don'ts 

Do:

  • Follow NFPA 1851 recommendations.
  • Pre-treat heavily soiled or spotted areas by soaking in an approved solution of detergent and water.
  • Keep water temperature under 40°C or 105°F.
  • Periodically run an empty cycle to clean out the extractor.
  • Use specialized detergents approved to clean PPE with a pH between 6.0 and 10.5.

Don't:

  • Stretch or wring out a wet hood.
  • Overload the extractor as it will result in inefficient cleaning.
  • Wash hoods or other PPE with personal items, in-home laundry, or at a laundromat.
  • Wash hoods with turnout gear outer shells, boots, suspenders, gloves, or any other materials containing hook/loop hardware.
  • Use chlorine bleach or solvents, as they may damage the protective qualities of the hood.
Download PDF version Download PDF version

In case you missed it

Innovative Fire Protection By WAGNER At LogiMAT 2025
Innovative Fire Protection By WAGNER At LogiMAT 2025

At the LogiMAT in Stuttgart from 11th to 13th March, WAGNER will be presenting innovative fire protection technologies and individual solutions for deep-freeze warehouses, high-bay...

The Importance Of Fire Protection To Minimize Damage After Natural Disasters
The Importance Of Fire Protection To Minimize Damage After Natural Disasters

There is a lot of studies and authority actions to have better responses after a natural disaster, including risk management, awareness, and preparedness especially in areas where...

Kidde's Game-Changing Inert Gas Solutions For Security
Kidde's Game-Changing Inert Gas Solutions For Security

The Kidde Fire Protection Natura™ Inert Gas System by Kidde Australia has transformed the way installers think about deploying inert gas fire suppression systems, deliverin...

vfd