The U.S. Chemical Safety and Hazard Investigation Board (CSB) released its final investigation report on the 2020 propylene release and explosion at the Watson Grinding facility in Houston, Texas, that fatally injured two workers and a nearby resident and damaged hundreds of neighboring homes.

The CSB’s final report highlights two key safety issues: the lack of a comprehensive process safety management program at the Watson Grinding facility to manage the risks of its thermal spray coating operations and an ineffective emergency response plan. 

CSB's final report on Watson Grinding facility fire

CSB Chairperson Steve Owens said, “Our investigation found that Watson Grinding did not have an effective program in place to assess potential hazards in its propylene process and did not have a mechanical integrity program or written operating procedures. This tragic incident was made even worse due to the lack of emergency response training for employees at the facility. Three lives were lost, and the surrounding community was put at risk as a result.”

Accidental release of propylene

CSB before the incident, a hose detached from its fitting inside a booth and released propylene

The incident occurred shortly after 4:30 am on January 23, 2020, when an accidental release of propylene accumulated and exploded inside the building at Watson Grinding.

The CSB found that prior to the incident, a hose disconnected from its fitting inside a coating booth and released propylene, a flammable hydrocarbon vapor, which accumulated inside the coating building at Watson Grinding.

By the time employees arrived at the facility early on the morning of January 23, an explosive concentration of propylene had formed inside the building. When one of the employees entered the building and turned on the lights, the flammable vapor ignited, triggering the explosion.

Cause of the accidental release

The CSB determined that the cause of the accidental release of propylene was a degraded and poorly crimped rubber welding hose that disconnected from its fitting inside a coating booth, combined with two other circumstances: (1) not closing the manual shutoff valve at the propylene storage tank at the conclusion of production operations the previous workday; and (2) the inoperative automated gas detection alarm, exhaust fan startup, and gas shutoff system.

Investigator-in-Charge, Benjamin Schrader said, “As highlighted in our safety issues, Watson Grinding did not effectively train its workers on the hazards of propylene, and on the morning of the incident these workers were not warned to evacuate, instructed to prevent others from entering the area, or informed to contact emergency responders when the propylene release was suspected.”

CSB’s report

CSB gives advice to enable both companies and standard-setting bodies to share information

As a result of its findings, the CSB is issuing recommendations to encourage both companies and standard-setting bodies to share information from the CSB’s report, as well as existing industry guidelines that emphasize the need for an effective process safety management system.

The CSB is an independent federal agency charged with investigating incidents and hazards that result or may result, in the catastrophic release of extremely hazardous substances.

core mission activities

The agency’s core mission activities include conducting incident investigations; determining the cause of the release; formulating preventive or mitigative recommendations based on investigation findings and advocating for their implementation; issuing reports containing the findings, conclusions, and recommendations arising from incident investigations; and conducting studies on chemical hazards.

The agency's board members are appointed by the president subject to Senate confirmation. The Board does not issue citations or fines but makes safety recommendations to companies, industry organizations, labor groups, and regulatory agencies such as OSHA and EPA.

Download PDF version Download PDF version

In case you missed it

Siemens Expands Fire Safety With Danfoss Acquisition
Siemens Expands Fire Safety With Danfoss Acquisition

Siemens Smart Infrastructure has completed the acquisition of Danfoss Fire Safety, a Denmark-based specialist in fire suppression technology. This strategic step will boost growth...

Specification And Installation: The Key To Effective Door Controls
Specification And Installation: The Key To Effective Door Controls

Safe and seamless movement in our built environment hinges on accurately specified and installed door hardware, explains Russell Marks, managing director of Boss Door Controls. Wi...

AEI Cables: Fire Safety And Building Compliance
AEI Cables: Fire Safety And Building Compliance

Many of the new requirements under the new Building Safety Act 2022 are still not understood by those making critical decisions in the fire safety supply chain, says cable supplier...

vfd