Download PDF version

The new Fire Safety Act 2021 came into force on 16th May 2022, and with it came a clearer direction about compliance. This article outlines the updates to the legislation and explain what this means for FMs.

The Grenfell Tower tragedy in 2017 and the subsequent enquiry highlighted the need for changes to the Regulatory Reform (Fire Safety) Order 2005. Sadly, it is only when events like this happen that legislation changes.

New Fire Safety Act 2021

The new Fire Safety Act 2021, which came into force in May 2022, amends the previous legislation and better defines the line between compliant and non-compliant. The responsibility for fire safety sits with the person in control of the premises, and they will expect their FM to help them protect their people and assets.

Conversely, being unable to produce evidence would be deemed non-compliant with the legislation

To comply, a responsible person must provide evidence that they have taken sound advice and acted upon it, when carrying out fire risk assessments. Conversely, being unable to produce evidence would be deemed non-compliant with the legislation. Therefore, the responsible person would have no defense against prosecution.

As well as a clearer understanding of compliance, the Act makes two amendments specific to buildings containing two or more flats with communal areas.

  • Firstly, it clarifies that the reference to communal areas includes the external walls, windows, doors, balconies, and anything else attached to the exterior of the building.
  • Secondly, it clarifies that the front door of flats should be considered part of the communal area.

Fire risk assessments

While FMs are experts in managing buildings for their customers, they are not necessarily experts in carrying out fire risk assessments or external structural checks. In this instance, FMs who manage residential properties should ensure that they take advice on these additional elements.

Qualified fire risk assessors can provide guidance relating to the communal areas, while advice on the structural components and building materials may need to come from a specialist in this area, such as a structural engineer. The structural advice is most relevant for buildings over 18 meters tall (seven floors), particularly when the Fire Safety (England) Regulations 2022 are enacted in January 2023.

Fire risk assessors at Chubb

They check physical fire detection systems, such as fire alarms, fire safety equipment, signage, and lighting

The fire risk assessors at Chubb generally have senior fire brigade or MOD backgrounds, and are all experts who understand how fire propagates around a building. They check physical fire detection systems, such as fire alarms, fire safety equipment, signage, and lighting.

Other aspects of the assessment will be structural, assessing the quality of compartmentalization to prevent fires from spreading. The fire risk assessments will also look at procedural elements and determine whether there is a fire plan in place, whether the evacuation procedure is effective, whether there is adequate training for personnel, and if these aspects are documented.

Other services are available, including one that looks specifically at Fire Doors Inspection that provides a detailed review of each door.

Keeping information secure

In domestic blocks over 18 meters high, the new legislation states that this information should be kept in secure information box accessible to the fire and rescue services. The information box should contain the name, address, and contact details of the responsible person and anyone else who can provide appropriate access to the premises.

The information box must be inspected and maintained by the responsible person at least annually. Essential fire safety equipment such as alarms and fire evacuation systems should be checked monthly to ensure they are in good working order.

There are further recommendations about fire door inspections in blocks over 11 meters high. Front doors of flats should be inspected annually, while internal fire doors should be checked more frequently, at least quarterly. In all domestic blocks with a communal area of any height, residents should be provided with information about their fire doors and the safe evacuation of the building.

Ensuring compliance

Many of the FM companies we work with have already adapted their requirements to manage these changes

Many of the FM companies we work with have already adapted their requirements to manage these changes, and I expect many others out there to do this too. But the overarching message is that everyone is on the same page regarding fire safety compliance.

FMs will be able to produce the documentation tenants need, provide evidence when required to show compliance, and demonstrate to their clients that they have experts carrying out fire risk assessment work to ensure their buildings are safe. Along with compliance and building trust with their clients, FMs can also benefit from reduced call-outs and false alarms, meaning reduced costs.

Making buildings safe for people to work and live

In summary, the amendment to the legislation aims to make buildings safe for people to work and live. Organization’s now have a much clearer picture of what is required by law to demonstrate fire safety compliance.

Chubb have always been a risk-averse organization and been at the forefront of new legislation. Recently, Chubb’s UK Lead for Training and Onboarding, Stuart Purton, created an online training module for employees, so they are equipped with the knowledge to provide expert advice to their customers about the new Act.

Chubb ensures their teams understand where new legislation has come from so they can clearly communicate it to the customers and provide the best advice and guidance to protect them.

Download PDF version Download PDF version

In case you missed it

Siemens Expands Into Fire Safety With Danfoss Buy
Siemens Expands Into Fire Safety With Danfoss Buy

Siemens Smart Infrastructure has agreed to acquire Danfoss Fire Safety, which specializes in fire suppression technology and is a subsidiary of Denmark-based Danfoss Group. The ac...

The Dingell Act's Impact: Practical Benefits For Fire Professionals
The Dingell Act's Impact: Practical Benefits For Fire Professionals

The Dingell Act, signed into law in 2019, has far-reaching implications, including effects on fire management and emergency services. Officially named the John D. Dingell, Jr. Cons...

Prevent Downtime With Teledyne FLIR Thermal Imaging
Prevent Downtime With Teledyne FLIR Thermal Imaging

When production halts unexpectedly, it disrupts the entire supply chain, causing delays in product delivery and potential loss of customer trust. Financially, the costs can be sub...

vfd