Kussmaul Electronics Co. Inc. 091-96-12 Load Manager 1H
Technical Specification
- Make: Kussmaul Electronics Co. Inc.
- Model code: 091-96-12
- Type: LOAD MANAGER 1H
Sheds 1 Load 30 Amp Relay Contact Rating 1.4 Volt Differential Between Relay Pull-In and Drop-Out Monitors 12 Volt System and Detects Low Voltage Relay Operates to Interrupt Load May Operate Remote Indicator Light Automatic Reset when Voltage Rises Load Management - Yes Loads - 1 Input - 12 Vdc Warranty - 3 Years Weight - .25 Lbs Indicators - Green - Normal , Red - Under Voltage Relay Contacts - 30 Amps Set Point - 12.0 Volts Adjustable Range - 10.5 To 13 Volts Hysteresis - 1.4 Volts The Load Manager 1H is a small economical assembly that monitors a D.C. voltage, and operates a relay when the voltage drops below its set point. This unit is unique in that a special high hysteresis feature maintains the relay in the energized condition, even if the voltage rises again. This prevents the load that has been shed, from being reenergized, until the sensed voltage rises more than 1.4 volts above the set point. Voltage set point and hysteresis are field adjustable. LED indicators are provided adjacent to the terminal strip, to indicate whether the system voltage is normal, or that the voltage has dropped below the set point. Installation instructions that are provided with each unit, contain a procedure for readjusting the under voltage set point.
Read moreMake | Kussmaul Electronics Co. Inc. |
---|---|
Manufacturer | Kussmaul Electronics Co. Inc. |
Category | Fire and Rescue>Apparatus and Equipment Accessories |
Model code | 091-96-12 |
Type | LOAD MANAGER 1H |
Additional info |
The Load Manager 1H is a small economical assembly that monitors a D.C. voltage, and operates a relay when the voltage drops below its set point. This unit is unique in that a special high hysteresis feature maintains the relay in the energized condition, even if the voltage rises again. This prevents the load that has been shed, from being reenergized, until the sensed voltage rises more than 1.4 volts above the set point. Voltage set point and hysteresis are field adjustable. LED indicators are provided adjacent to the terminal strip, to indicate whether the system voltage is normal, or that the voltage has dropped below the set point. Installation instructions that are provided with each unit, contain a procedure for readjusting the under voltage set point. |
Download PDF version Download PDF version |
- See other Kussmaul Electronics Co. Inc. products
- Kussmaul Electronics Co. Inc. Rescue/RIT Accessories
- Kussmaul Electronics Co. Inc. Monitors
- Kussmaul Electronics Co. Inc. Fire Station Equipment Accessories
- Kussmaul Electronics Co. Inc. Compressors
- Kussmaul Electronics Co. Inc. Warning Lights & Sirens
The New Future For Fire Agencies
DownloadThe Eight Key Trends in Fire Detection in 2023
DownloadA Digital Platform to Improve Fire Safety Compliance and Inspections
DownloadOvercoming the Challenges of Fire Safety in the Paper Industry
DownloadCarbon Monoxide: Creeping Killer Caught In The Act
Download