Kussmaul Electronics Co. Inc. 091-85-12 Low Voltage Alarm
Technical Specification
- Make: Kussmaul Electronics Co. Inc.
- Model code: 091-85-12
- Type: LOW VOLTAGE ALARM
Sheds 1 Load 30 Amp Relay Contact Rating Meets NFPA 1901 Requirements Detects Low Battery Voltage Operates any Indicator or Alarm Easy Installation Alarm/Display - Yes Load Management - Yes Loads - 1 Input - 12 Vdc Warranty - 3 Years Weight - .25 Lbs Relay Contacts - 30 Amps Set Point - 11.8 Volts On Delay - 120 Seconds The Low Voltage Alarm detects when the battery voltage drops below a threshold, and remains low for 120 seconds. At that time, a relay is operated, which may be connected to the low voltage indicator and alarm. Available for either 12, or 24 volt electrical systems. The unit contains LED indicators to aid in installation and test. A green indicator is illuminated whenever the voltage is normal. When the voltage drops below the setpoint, and remains low for 120 seconds, the green LED is extinguished, and the red LED is illuminated. The setpoint, and time delay, meet the requirements of NFPA 1901, paragraph 9-3.3. Easily installed, the Low Voltage Alarm requires only two wires to sense the battery voltage. The 30 ampere contacts on the relay provide ample capacity to operate the low voltage alarm and indicator. Availability of a normally closed contact, in addition to the normally open contact, permits a wide variety of connections in the load circuit.
Read moreMake | Kussmaul Electronics Co. Inc. |
---|---|
Manufacturer | Kussmaul Electronics Co. Inc. |
Category | Fire and Rescue>Apparatus and Equipment Accessories |
Model code | 091-85-12 |
Type | LOW VOLTAGE ALARM |
Additional info |
The Low Voltage Alarm detects when the battery voltage drops below a threshold, and remains low for 120 seconds. At that time, a relay is operated, which may be connected to the low voltage indicator and alarm. Available for either 12, or 24 volt electrical systems. The unit contains LED indicators to aid in installation and test. A green indicator is illuminated whenever the voltage is normal. When the voltage drops below the setpoint, and remains low for 120 seconds, the green LED is extinguished, and the red LED is illuminated. The setpoint, and time delay, meet the requirements of NFPA 1901, paragraph 9-3.3. Easily installed, the Low Voltage Alarm requires only two wires to sense the battery voltage. The 30 ampere contacts on the relay provide ample capacity to operate the low voltage alarm and indicator. Availability of a normally closed contact, in addition to the normally open contact, permits a wide variety of connections in the load circuit.
|
Download PDF version Download PDF version |
- See other Kussmaul Electronics Co. Inc. products
- Kussmaul Electronics Co. Inc. Rescue/RIT Accessories
- Kussmaul Electronics Co. Inc. Monitors
- Kussmaul Electronics Co. Inc. Fire Station Equipment Accessories
- Kussmaul Electronics Co. Inc. Compressors
- Kussmaul Electronics Co. Inc. Warning Lights & Sirens
The New Future For Fire Agencies
DownloadThe Eight Key Trends in Fire Detection in 2023
DownloadA Digital Platform to Improve Fire Safety Compliance and Inspections
DownloadOvercoming the Challenges of Fire Safety in the Paper Industry
DownloadCarbon Monoxide: Creeping Killer Caught In The Act
Download