Kussmaul Electronics Co. Inc. 091-75-AT Load Manager Mark IV-AT

Technical Specification

Features:
  • Make: Kussmaul Electronics Co. Inc.
  • Model code: 091-75-AT
  • Type: LOAD MANAGER MARK IV-AT
Additional info:

Sheds 9 Loads Automatically Sheds Loads to Prevent Electrical System Overload Eliminates Power Surges in Electrical System Provides High Idle Control to Increase Alternator Output Before Shedding Loads Load Shed Priority Programmable Independent of Sequencer Load Management - Yes Loads - 9 Input - 12 Vdc Output - 40 Ohms To Drive Relays Warranty - 3 Years Weight - 2 Lbs The Load Manager Mark IV AT is a 9-channel sequencer and load-shedding controller operating 9 vehicle installed relays. In addition a High Idle control speeds up the engine to increase alternator output prior to shedding loads. Upon closing a Master Switch to initiate the sequencing, the 9 outputs are energized sequentially at approximately 1/2 second intervals. Upon shutdown they are de-energized similarly. In addition the Load Manager Mark IV AT monitors the vehicle's battery voltage. When electrical loads exceed alternator output, the voltage drops. Load Manager Mark IV AT senses this and if brake/neutral safety switch/pump interlocks are satisfied, then a high idle output is generated and the load shedding begins. If the interlocks are not satisfied, then no high idle output is obtained but load shedding proceeds. A programming switch permits the installer to limit the sequencing to 5, 6, 7, 8, or all 9 outputs. Sequencing operation is completely independent of the load shedding control. The 9 outputs are shed individually when the system voltage sensed is low. The priority is completely random so that any output can be programmed to be the first to shed. Any other output can be second and so forth. Programming is easily changed even after installation with the DIP switches provided. If some critical loads, which the installer determines must never be shed, are connected to the Load Manager Mark IV AT, the programming switches may be set to never shed those loads. An indicator is included to signal when the Load Manager Mark IV AT is active and when it is in the Load Reduce mode.

Read more
Make Kussmaul Electronics Co. Inc.
Manufacturer Kussmaul Electronics Co. Inc.
Category Fire and Rescue>Apparatus and Equipment Accessories
Model code 091-75-AT
Type LOAD MANAGER MARK IV-AT
Additional info
  • Sheds 9 Loads
  • Automatically Sheds Loads to Prevent Electrical System Overload
  • Eliminates Power Surges in Electrical System
  • Provides High Idle Control to Increase Alternator Output Before Shedding Loads
  • Load Shed Priority Programmable Independent of Sequencer
  • Load Management - Yes
  • Loads - 9
  • Input - 12 Vdc
  • Output - 40 Ohms To Drive Relays
  • Warranty - 3 Years
  • Weight - 2 Lbs

The Load Manager Mark IV AT is a 9-channel sequencer and load-shedding controller operating 9 vehicle installed relays. In addition a High Idle control speeds up the engine to increase alternator output prior to shedding loads. Upon closing a Master Switch to initiate the sequencing, the 9 outputs are energized sequentially at approximately 1/2 second intervals. Upon shutdown they are de-energized similarly.

In addition the Load Manager Mark IV AT monitors the vehicle's battery voltage. When electrical loads exceed alternator output, the voltage drops. Load Manager Mark IV AT senses this and if brake/neutral safety switch/pump interlocks are satisfied, then a high idle output is generated and the load shedding begins. If the interlocks are not satisfied, then no high idle output is obtained but load shedding proceeds.

A programming switch permits the installer to limit the sequencing to 5, 6, 7, 8, or all 9 outputs. Sequencing operation is completely independent of the load shedding control. The 9 outputs are shed individually when the system voltage sensed is low. The priority is completely random so that any output can be programmed to be the first to shed. Any other output can be second and so forth. Programming is easily changed even after installation with the DIP switches provided. If some critical loads, which the installer determines must never be shed, are connected to the Load Manager Mark IV AT, the programming switches may be set to never shed those loads.

An indicator is included to signal when the Load Manager Mark IV AT is active and when it is in the Load Reduce mode.