Sue Corrick of Allegion UK explores the evolution of panic and emergency exit hardware, examining the specification and installation points that decision-makers must consider throughout modern applications.
The swift evacuation of a building and its occupants is critical in an escape or emergency situation. For decades, escape doors and exit hardware have been co-dependent in their purpose of facilitating safe egress when it matters most.
Elements of public safety
In fact, exit hardware has been providing users with a safe means of escape since the early 20th century. Following a string of high-profile disasters, including the infamous Iroquois Theater Fire in Chicago in 1903, the conditions of the world’s built environment and its emergency exits were more closely inspected as crucial elements of public safety, in large part to The National Fire Protection’s (NFPA) Life Safety Code in the US. Incidentally, this period was a catalyst for change in the exit device industry, with the world’s first panic bar made available in an assortment of configurations in 1908, courtesy of Von Duprin.
Exit hardware is more conventionally categorized as panic hardware |
The conditions of the world’s built environment and its emergency exits were more closely inspected
The term ‘exit hardware’ is more conventionally categorized as either panic hardware or emergency exit hardware. With distinguishing characteristics and features, both categories of exit hardware provide users with a safe means of escape, and both have come a long way since their inception all those years ago. As such, selecting the most suitable solutions can be a challenge for modern projects, and decision-makers are reminded to consider a number of key factors.
Distinctive door hardware
In a fire scenario, a building’s evacuation methods must be as straightforward and defined as possible. When a person reaches an exit door, it is essential that the door can be operated with ease, regardless of who is operating it and where it is being used. While all exit hardware plays an integral role in this process, decision-makers must consider a building’s type, application, and occupation levels when selecting between panic and emergency exit hardware, since there are meaningful differences between the two.
Panic hardware, for example, is a type of exit device that has been designed to provide safe and effective escape through doorways with minimum effort and without prior knowledge of its operation. Panic hardware devices come in the form of horizontal push or touch bars and are commonly applied to outward opening doors in public-facing buildings or buildings with more than 60 occupants, where they can be operated by untrained people or members of the public, ensuring safe and effective escape. As such, panic device push and touch bars should be installed to provide the maximum effective length, but never less than 60% of the door leaf width, as stipulated by BS EN 1125 and harmonized CE and UKCA designated standards.
levels of accessibility and security
For spaces where the opening width is limited, a non-intrusive touch bar can also be a practical option
With its size, panic hardware is typically easier to see and operate than some emergency exit hardware devices. With this in mind, decision-makers should often choose to implement panic hardware solutions in busy public spaces such as hospitals, shops, and places of entertainment where usability is paramount. For spaces where the opening width is limited, a non-intrusive touch bar can also be a practical option. Furthermore, in cases where users may wish to gain access from the outside of a door with a panic bar, an outside access device can also be applied to maintain equal levels of accessibility and security.
Emergency exit hardware is often applied in buildings with less than 60 occupants |
Emergency exit hardware is dissimilar in a few areas. Typically smaller devices, emergency exit hardware is often applied in buildings with less than 60 occupants or non-public buildings, where its users have prior knowledge of the building’s layout, its escape routes and the exit devices placed throughout them. Think of office spaces and warehouses for example. In design, emergency exit devices commonly comprise of a single push pad with a rim latch or a lever handle operating a mortice escape lock or night latch and allow for single-action egress. Where emergency exit hardware is applied, it must be certified to BS EN 179.
Emergency exit hardware is dissimilar in a few areas |
Information is key
Decision-makers are urged to select door hardware devices that are tested to EN 1125
As per Approved Document B, all doors located on an escape route must have suitable exit hardware installed. And so, with varied solutions available, specification teams must also consider the door in which an exit device will be fitted. Will the device be applied to single or double doors? What are the height and width requirements? And does the device need anti-thrust bolts for added levels of security? Above all, does it meet the latest fire safety standards?
BS EN 1125 and BS EN 179 standards provide important safety and reliability |
If in doubt, decision-makers are urged to select door hardware devices that are tested to EN 1125 while referring to harmonized and designated standards if they feel unsure. BS EN 1125 and BS EN 179 standards provide important safety and reliability details on panic hardware and emergency exit devices respectively, reviewing classification, product performance requirements, test cycles, and test methods as standard. For traceability purposes, decision-makers and end-users can also review the UKCA and CE marks on exit hardware to find its fire rating, certificate numbers, and the manufacturer’s details.
Code for Construction Product Information
When it comes to induction, teams are advised to use the support that’s made available by plants
Typically, dependable devices will be supplied with full product information from the manufacturer - including Declaration of Performance (DoP), Certifire certification, and product data sheets - showing that they comply with the necessary harmonized standards. The Code for Construction Product Information has been designed to assist people in reviewing and selecting door hardware solutions transparently and can also be referred to for clear, accurate, and up-to-date product information, to ensure door hardware solutions conform to the latest building standards and UKCA and CE certifications.
Similarly, when it comes to installation, teams are advised to use the support that’s made available by manufacturers, in the form of helpful online tools and product guides. This further helps to ensure there are no oversights made at the installation stage that could develop into life-threatening issues later down the line.
fire door’s hardware devices
Under current EN standards, it is also recommended that all of a fire door’s hardware devices should be supplied from the same manufacturer and tested together to ensure the full doorset remains compliant with the application.
As with all other fire door hardware, there is no one-size-fits-all solution where exit hardware is concerned. Panic hardware and emergency exit hardware play crucial, but separate roles in a building’s evacuation routes and as such, both decision-makers and end-users alike must be able to distinguish between them both. After all, it could make a difference when it comes to escape.