Godiva Prima P2-3010 multi-pressure fire pump

Technical Specification

Features:
  • Make: Godiva
  • Model code: Prima P2-3010
  • Max. Operating Pressure (psi): 201~300
  • Stages: Multi
  • Rating (GPM): 1001~2000
Additional info:

Priming performance range: 7.5 m. Priming speed (recommended): 2500 rpm. Maximum suction pressure: 12 bar. Maximum recommended speed: 3600 rpm. Maximum outlet pressure (high pressure): 54.5 bar. Maximum flow (low pressure): 4200 lpm. Maximum flow (high pressure): 770 l/min. Weight: 117 kg. Dimensions: 806 x 764 x 817 mm. Thermal relief valve activation: 42ºC or 74ºC. Meets with European and International standards.

Read more
Make Godiva
Manufacturer Godiva Ltd
Category Fire and Rescue>Pumps
Model code Prima P2-3010
Max. Operating Pressure (psi) 201~300
Stages Multi
Rating (GPM) 1001~2000
Mounting Rear Mount
Additional info

Priming performance range: 7.5 m. Priming speed (recommended): 2500 rpm. Maximum suction pressure: 12 bar. Maximum recommended speed: 3600 rpm. Maximum outlet pressure (high pressure): 54.5 bar. Maximum flow (low pressure): 4200 lpm. Maximum flow (high pressure): 770 l/min. Weight: 117 kg. Dimensions: 806 x 764 x 817 mm. Thermal relief valve activation: 42ºC or 74ºC. Meets with European and International standards.