  • Make: Edwards Signaling
  • Model code: RPM
  • Type: E-FSC Series Reverse Polarity Module,
Additional info:

RPM The Edwards E-FSC fire alarm family consists of 3, 5 and 10 zone conventional fire alarm control panels, an integrated DACT/Dialer, serial annunciator modules, and serial remote relay modules. All of these components are microprocessor-controlled. The E-FSC family is suitable for both new and retrofit installations.E-FSC Series Panels incorporate features designed to simplify installation, operation and maintenance. These include front panel programming, one person walk testing, and selectable IDC and NAC types. In addition, when used with Edwards CleanMe® -compatible smoke detectors, E-FSC provides analog type features such as remote maintenance alert and automatic drift compensation that reduces false alarms and simplifies maintenance calls.E-FSC502 and E-FSC1004 panels support Class A operation by combining pairs of on-board initiating circuits (IDCs) or notification circuits (NACs) to provide the necessary Class A circuits.FEATURES & SPECS Available in 3, 5, and 10 IDC models IDC or NAC pairs convertible to single Class A circuits (10 and 5 IDC panels only) Combination Waterflow and Supervisory IDCs reduces wire and zone counts NACs programmable by zone and individually selectable for Genesis, continuous, temporal outputs, or coded Front panel programmable Optional fully integrated DACT/Dialer for remote PC programming Genesis option allows precision synchronization and audible silence over two wires without additional modules On-board relays for Alarm, Supervisory, and Trouble Optional serial bus relay modules are programmable for common or zone activation Optional serial bus remote annunciator family Expandable power supply on 10 IDC panel Trim ring available for semi-flush mounting Supports 2M, "SC", 2400, 500, and 700 series detectors Operating temperature range

Read more
Make Edwards Signaling
Manufacturer Edwards Signaling
Category Fire and Rescue>Apparatus and Equipment Accessories
Model code RPM
Type E-FSC Series Reverse Polarity Module,
Additional info

RPM The Edwards E-FSC fire alarm family consists of 3, 5 and 10 zone conventional fire alarm control panels, an integrated DACT/Dialer, serial annunciator modules, and serial remote relay modules. All of these components are microprocessor-controlled. The E-FSC family is suitable for both new and retrofit installations.

E-FSC Series Panels incorporate features designed to simplify installation, operation and maintenance. These include front panel programming, one person walk testing, and selectable IDC and NAC types. In addition, when used with Edwards CleanMe® -compatible smoke detectors, E-FSC provides analog type features such as remote maintenance alert and automatic drift compensation that reduces false alarms and simplifies maintenance calls.

E-FSC502 and E-FSC1004 panels support Class A operation by combining pairs of on-board initiating circuits (IDCs) or notification circuits (NACs) to provide the necessary Class A circuits.

FEATURES & SPECS

  • Available in 3, 5, and 10 IDC models
  • IDC or NAC pairs convertible to single Class A circuits (10 and 5 IDC panels only)
  • Combination Waterflow and Supervisory IDCs reduces wire and zone counts
  • NACs programmable by zone and individually selectable for Genesis, continuous, temporal outputs, or coded
  • Front panel programmable
  • Optional fully integrated DACT/Dialer for remote PC programming
  • Genesis option allows precision synchronization and audible silence over two wires without additional modules
  • On-board relays for Alarm, Supervisory, and Trouble
  • Optional serial bus relay modules are programmable for common or zone activation
  • Optional serial bus remote annunciator family
  • Expandable power supply on 10 IDC panel
  • Trim ring available for semi-flush mounting
  • Supports 2M, "SC", 2400, 500, and 700 series detectors
  • Operating temperature range