Cervinka 0108 AUTOMATIC EXTINGUISHING SYSTEM BUS VIPER 4 KG

Technical Specification

Features:
  • Make: Cervinka
  • Model code: 0108
Additional info:

Activation temperature: above 120 ° C Detection tube: 4 - 6m Activation after the fire: 6 - 10sec Working pressure in system: 10 bar (1,0Mpa) The system operates in automatic mode through a detector tube that is kept in the engine compartment This tube is used as a boot device of system. When the temperature increases above 180 to 200 ° C, occurs to soften of tube.respectively. burn through, thus decrease pressure in the tube and gives signal to fire system to which the device is connected and starts extinguishing Also is possible hand startup through information system, which is mounted near to the driver When activated extinguishing in the engine compartment the information system informs the driver by sound and light signal. The system operates automatically Clean extinguishing agent spontaneously evaporates The extinguishing agent is given concentration is absolutely harmless in terms of health for the passangers Easy maintenance and service Safety way to protect the passengers and the vehicle     

Read more
Make Cervinka
Manufacturer Cervinka - Czech Republic s.r.o.
Category Fire Protection>Extinguishers
Model code 0108
Additional info

Activation temperature: above 120 ° C

Detection tube: 4 - 6m

Activation after the fire: 6 - 10sec

Working pressure in system: 10 bar (1,0Mpa)

The system operates in automatic mode through a detector tube that is kept in the engine compartment

This tube is used as a boot device of system. When the temperature increases above 180 to 200 ° C, occurs to soften of tube.respectively. burn through, thus decrease pressure in the tube and gives signal to fire system to which the device is connected and starts extinguishing

Also is possible hand startup through information system, which is mounted near to the driver

When activated extinguishing in the engine compartment the information system informs the driver by sound and light signal.

  • The system operates automatically
  • Clean extinguishing agent spontaneously evaporates
  • The extinguishing agent is given concentration is absolutely harmless in terms of health for the passangers
  • Easy maintenance and service

Safety way to protect the passengers and the vehicle 

 

 

Download PDF version Download PDF version