1 Jul 2024

In the world of firefighting, knowledge and tactics are always evolving, and the importance of staying informed cannot be overstated. The task of ventilation (horizontal and vertical) in residential structures has seen significant advancements through extensive research conducted by the UL Fire Safety Research Institute (FSRI). This research has shed light on the intricacies of ventilation and its profound impact on fire dynamics.

While the core task of ventilation remains largely unchanged, the understanding of when, where, and how to perform ventilation has undergone a transformation. They now have a comprehensive grasp of both the positive and negative effects of ventilation on fire incidents.

Historical Perspective

The fire service’s ongoing growth relies on scientific insights to enrich the wisdom of the fireground

In the past, firefighters learned to prioritize early and frequent ventilation, with the belief that more ventilation is always better. These practices were largely based on anecdotal experience and lacked a solid foundation in scientific data. Fire service members were left without a clear understanding of the actual impact of ventilation on fire dynamics.

The fire service’s ongoing evolution relies on scientific insights to enhance the understanding of the fireground. One of the crucial shifts in the comprehension of ventilation is the realization that it does not equate to cooling, as previously believed.

Vertical ventilation

This misconception was rooted in two primary assumptions: first, that vertical ventilation lifts the neutral plane, and second, that ventilation creates a cooling effect due to the influx of fresh air into the building.

However, modern research contradicts these assumptions, revealing that ventilation primarily fuels the fire. This actually leads to increased temperatures. This misconception was also rooted in the experience. They have all been in a position and called for vertical ventilation. Once the “lift” began, we felt the “relief” or cooling of the environment. This lift, as we call it, is actually a greater influx of air providing for the misconception of relief or cooling.

The Catalyst: UL FSRI

The pivotal turning point in the account of ventilation came via research led by the UL FSRI

The pivotal turning point in the understanding of ventilation came through research conducted by the UL FSRI. Its groundbreaking technical report, titled Study of the Effectiveness of Fire Service Vertical Ventilation and Suppression Tactics in Single Family Homes, played a pivotal role in reshaping the approach to ventilation.

This research has been consistently validated through various studies and live fire tests, including collaborations with the Fire Department of New York (FDNY) on Governors Island.

Coordination: The Key to Effective Ventilation

The primary objective of ventilation is to control a building’s behavior. This increases firefighter safety and creates a safer environment for potential victims. Door control plays a pivotal role in this process as well, keeping the fire in a ventilation-limited state until firefighters are ready to proceed. Effective coordination between ventilation and fire attack is essential. Here are a few pointers for the ventilation crew to follow:

  • Make sure the charged hoseline is in place.
  • Check to confirm the entry door is unlocked/forced but controlled in the closed position.
  • Be ready to create an opening.

Rapid and safer ventilation

Controlling the door limits the fresh air available to the fire, reducing the flow path

Controlling the door limits the fresh air available to the fire, reducing the flow path. This door control is a critical component of coordinated ventilation and fire attacks. Once water is applied to the fire, it is no longer ventilation-limited, and it allows for more rapid and safer ventilation. However, achieving proper coordination may pose challenges due to staffing levels.

Vertical ventilation control does not mean reporting to the roof and waiting. They can still cut the ventilation hole. However, hold off on the task of “pushing through” the ceiling until water is in place, flowing or directed to by the engine company. Tactically, the same discipline is necessary for the outside vent (OV) firefighter, the firefighter who is tasked with horizontal ventilation by “taking the windows.” The OV must still negotiate and access his position and be prepared to take the windows. However, the windows should be kept intact until either directed by the inside team or until water is flowing into the area.

Door Control: A Critical Task

Door control is a fundamental aspect of modern firefighting, but it comes with its own set of challenges. Firefighters often carry wedges for door control, a time-honored practice that emphasizes the importance of maintaining door integrity.

Designating a firefighter to control the door at the primary entry/exit point is a common approach. This firefighter evaluates conditions and ensures that the door remains open to control the flow of water. Effective communication with the hose team is essential for successful coordination.

Interior firefighters

Further, interior firefighters should prioritize closing doors as they advance toward the fire

Additionally, interior firefighters should prioritize closing doors as they advance toward the fire. This limits flow paths and fire spread, reducing the risk of getting trapped. If staffing does not permit a dedicated door control position, the hoseline can often keep the door from closing completely.

It is critical for firefighters to recognize the door as a vent opening. This tactical mindset enhances firefighter and victim safety; however, it goes against many of the tactical mindsets.

Challenges to prevent firefighters

When door control is deployed, the ability to see clearly as they navigate the dwelling diminishes. This, in turn, presents challenges that prevent some firefighters from seeing the true necessity.

Many firefighters are concerned that a decrease in their ability to see will slow their search or attack team advancement. This highlights the necessity for quality search training in environments where vision is impaired. This also highlights the necessity for training moving hoselines in similar environments—not just parking lots!

Key Findings of UL Ventilation Research

  • Fire Intensification with Ventilation
    • A fundamental revelation is that providing a ventilation opening allows the fire to grow more rapidly. Ventilation offers the fire more oxygen, accelerating its heat release rate (HRR). It’s essential to recognize that modern interior furnishings are major contributors to this increased HRR, making it impossible to reduce temperatures significantly through ventilation alone.
  • Coordination of Ventilation and Fire Attack
    • A critical shift in tactics is the necessity for coordinated ventilation and fire attacks. The era of spontaneously breaking windows or creating openings during a walk-around is over. Effective water application is key to fire control, allowing safer and more controlled ventilation.
  • Fire Attack Crew Entrance as Ventilation
    • A simple but crucial principle is that if firefighters force the door, they must also control it. This requires an understanding that there’s an average of 100 seconds to apply water before a flashover becomes a real danger once an opening is made. This average depends on many variables, including room size, interior finishings, amount of fuel, and distance from the ventilation opening.
  • External Water Application for Self-Vented Fires
    • When the fire has already self-vented through a window, the best approach may be to apply water from the exterior to “soften” the target before entering the structure. This minimizes the risk of the fire spreading to the attic if vinyl soffits are present or autoexposing to upper floors. It’s worth noting that putting water into a fire environment with a straight stream pattern doesn’t push the fire but instead reduces interior temperatures, enhancing victim survivability.
    • However, it is also important to remember that if the fire is venting from the rear of the structure, it may be faster to stretch via the inside to knock down the fire. This highlights the necessity to train for both interior attack and external water applications. They must have a clear understanding of the time it takes them and their crew to get water onto the fire in many different scenarios.
  • Vent-Enter-Isolate-Search (VEIS) Protocol
    • During initial VEIS operations, refraining from breaking glass with the ladder is critical. Breaking the window should be the last step before entering the structure. Quick isolation by closing the interior door is essential for safety once firefighters have entered the room via the ladder. Proper communication, coordination, and assessment of interior conditions enable search crews to make tactical decisions and navigate through the structure efficiently.

Alternative Door Control Devices

Each department operates differently and has different challenges

In the quest for effective door control, various devices and methods have emerged. Dr. Michael Reick’s invention, the door curtain, has gained traction in Germany and is an option for departments with limited staffing. During testing, this curtain technology demonstrated its ability to control the flow path, limit airflow, and slow fire growth. All of these provide valuable time for firefighting operations.

Many departments do not have the necessary staffing to position a firefighter in the door control position. Each department operates differently and has different challenges. However, each department needs to prioritize achieving door control using the resources they have available.

Looking Ahead

Modern firefighting tactics require a comprehensive understanding of ventilation, coordination, and control. Ventilation is no longer a standalone tactic but must be carefully timed with water application. The 100-second window from ventilation to flashover emphasizes the critical need for precise coordination. Door control, whether achieved through wedges, designated firefighters, or innovative devices like the door curtain, plays a pivotal role in firefighter safety and the success of interior firefighting operations.

While traditional ventilation practices still have their place, the evolving science of firefighting necessitates a thoughtful and coordinated approach to keep firefighters and civilians safe on the fireground. Recognizing the positive and negative effects of every action is key to controlling fire behavior and ensuring a swift and efficient response to fire incidents.