19 Oct 2017

"The fact that no fire has broken out for a long time does not mean that there is no danger; rather, it is a stroke of luck for operators, and one that can end at any time," says Marco van Lier from the General Association of the German Insurance Industry.

If a fire breaks out, there is a risk that the IT infrastructure in data centers will be damaged. The power outage that can occur in the event of a fire causes particularly great damage due to the resulting data loss.

fire protection solutions

The WAGNER Group will be presenting fire protection solutions of the future that are specifically designed to protect data centers and prevent data loss in the event of a fire at the DataCentre World in Frankfurt from November 28-29, 2017. 

Under the motto "For the data center of the future," the system manufacturer will be showcasing suitable fire protection solutions - especially for value-focused and process-sensitive areas.

Aspirating smoke detection system

The false alarm-proof aspirating smoke detectors of the TITANUS® family offer preventive basic protection

TITANUS®: a reliable detector for server cabinets. The false alarm-proof aspirating smoke detectors of the TITANUS® family offer preventive basic protection in almost all areas of application. The detection units of the aspirating smoke detection system detect even the smallest amounts of pyrolysis particles based on samples taken from the ambient air. 

This makes TITANUS® up to 2,000 times more sensitive than conventional point detectors, works even in the most difficult environmental conditions and can be installed flexibly.

OxyReduct® system

TITANUS RACK·SENS® is a reliable detector for implementation in server cabinets. The 44.45 mm high fire detector (one height unit) can optionally be expanded to include fire fighting with the extinguishing gas Novec™ at two height units.

Visitors can experience live how TITANUS RACK·SENS® works at the WAGNER Group exhibition stand. Actively prevent fires with OxyReduct® The internationally successful OxyReduct® system starts before a fire starts and protects IT systems against operational interruptions and data loss. 

ignition limit of the materials

The technology behind OxyReduct® is the clever key to prevent a fire from growing in the first place

The technology behind OxyReduct® is a clever solution to prevent a fire from developing in the first place. To do this, the oxygen content in the area to be protected is permanently reduced below the ignition limit of the materials present there and kept at this level in a controlled manner. 

The nitrogen required to reduce the oxygen is generated on site from the ambient air as required.

With FirExting®: extinguish fires

WAGNER is also presenting a gas extinguishing system for data centers at the trade fair that works efficiently and, above all, without leaving any residues: FirExting®. Depending on the operator's requirements and the individual conditions on site, CO2, Novec 1230 and, above all, nitrogen are used as extinguishing gases.

The inert gas nitrogen enables multi-stage fire protection concepts in conjunction with an OxyReduct® system. If fire detectors such as TITANUS® detect smoke development, a FirExting® extinguishing system can be used to quickly reduce the oxygen level to a concentration that can be used to extinguish the fire. The OxyReduct® system can then maintain the reduced oxygen concentration in the room for a long time until the cause of the fire is located and countermeasures are initiated.