Kussmaul Electronics Co. Inc. 091-167-12 Load Manager 1HP

Technical Specification

Features:
  • Make: Kussmaul Electronics Co. Inc.
  • Model code: 091-167-12
  • Type: LOAD MANAGER 1HP
Additional info:

Sheds 1 Load 75 Amp Relay Contact Rating Low Voltage Disconnect Prevents Inadvertent Battery Discharge Encapsulated Electronics Engine Start Shutdown Protected Load Management - Yes Loads - 1 Input - 12 Vdc Warranty - 3 Years Weight - .5 Lbs Relay Contacts - 75 Amps Set Point - 11 Volts Load Shed Voltage - 11.5 To 12.8 Volts Starter Inhibit - Load Will Not Be Shed Due To Low Voltage While Engine Is Being Cranked (Eliminates Computer Rebooting) The Model 091-167-12, Load Manager 1HP, is a compact, encapsulated load manager, that monitors the battery voltage, and operates a 75 ampere relay to de-energize a load when the voltage drops. With the engine running, and battery above 12.8 volts, the relay contacts are closed, and power is supplied. With the engine stopped, the loads on the battery will decrease the battery voltage. When the voltage drops below 11.5 volts, the relay contacts open to prevent complete discharge of the battery. A connection to the vehicle's starter prevents opening of the relay contacts during cranking, when a low voltage is expected. Encapsulation of the electronic circuits protects them from water damage, and permits mounting the Load Manager 1HP under the hood, or other locations.

Make Kussmaul Electronics Co. Inc.
Manufacturer Kussmaul Electronics Co. Inc.
Model code 091-167-12
Type LOAD MANAGER 1HP
Additional info
  • Sheds 1 Load
  • 75 Amp Relay Contact Rating
  • Low Voltage Disconnect
  • Prevents Inadvertent Battery Discharge
  • Encapsulated Electronics
  • Engine Start Shutdown Protected
  • Load Management - Yes
  • Loads - 1
  • Input - 12 Vdc
  • Warranty - 3 Years
  • Weight - .5 Lbs
  • Relay Contacts - 75 Amps
  • Set Point - 11 Volts
  • Load Shed Voltage - 11.5 To 12.8 Volts
  • Starter Inhibit - Load Will Not Be Shed Due To Low Voltage While Engine Is Being Cranked (Eliminates Computer Rebooting)

The Model 091-167-12, Load Manager 1HP, is a compact, encapsulated load manager, that monitors the battery voltage, and operates a 75 ampere relay to de-energize a load when the voltage drops. With the engine running, and battery above 12.8 volts, the relay contacts are closed, and power is supplied.

With the engine stopped, the loads on the battery will decrease the battery voltage. When the voltage drops below 11.5 volts, the relay contacts open to prevent complete discharge of the battery. A connection to the vehicle's starter prevents opening of the relay contacts during cranking, when a low voltage is expected.

Encapsulation of the electronic circuits protects them from water damage, and permits mounting the Load Manager 1HP under the hood, or other locations.