Godiva Prima P2-2010 fire pump for rear or midship mounting

Technical Specification

Features:
  • Make: Godiva
  • Model code: Prima P2-2010
  • Mounting: Rear Mount
  • Max. Operating Pressure (psi): 201~300
  • Stages: Multi
Additional info:

Priming performance range: 7.5 m. Priming speed (recommended): 2500 rpm. Maximum suction pressure: 12 bar. Maximum recommended speed: 3600 rpm. Maximum outlet pressure (high pressure): 54.5 bar. Maximum flow (high pressure): 770 l/min. Weight: 105 kg. Dimensions: 748 x 580 x 782 mm. Thermal relief valve activation: 42ºC or 74ºC. Meets with European and International standards.

Make Godiva
Manufacturer Godiva Ltd
Model code Prima P2-2010
Mounting Rear Mount
Max. Operating Pressure (psi) 201~300
Stages Multi
Rating (GPM) 501~1000
Additional info

Priming performance range: 7.5 m. Priming speed (recommended): 2500 rpm. Maximum suction pressure: 12 bar. Maximum recommended speed: 3600 rpm. Maximum outlet pressure (high pressure): 54.5 bar. Maximum flow (high pressure): 770 l/min. Weight: 105 kg. Dimensions: 748 x 580 x 782 mm. Thermal relief valve activation: 42ºC or 74ºC. Meets with European and International standards.